AI-generated
  1. Home
  2. Logistics property: what matters

Knowledge

Logistics property. What matters.

Height, floor, doors, fire safety, energy and permits decide whether a building suits an operation. An overview of the specifications that count when searching, leasing and investing.

AI-generated illustration: warehouse with racking

Why specifications determine value

A logistics property is a tool. How well it works depends less on floor area than on height, floor, loading, fire safety and permits. Two buildings of the same size can differ considerably in throughput, running costs and re-lettability.

For occupiers, fit with the operation is decisive. For owners and investors, re-lettability matters most: the more occupiers can run a building without major alterations, the more stable its letting and value.

3D

The warehouse as a model

A typical modern logistics building, outside and inside. Rotate, zoom, click the points. Each point explains a feature and leads to the glossary.

Drag to rotate, scroll or pinch to zoom.

Your browser cannot display the 3D model. All points are listed below.

All points at a glance
  1. A loading point at truck bed height where vehicles dock directly. In the glossary

  2. A curtain or cushion system closing the gap between vehicle and wall. In the glossary

  3. A door at yard level through which vehicles can drive into the hall. In the glossary

  4. The yard in front of the doors where trucks turn and dock. In the glossary

  5. Parking areas for waiting trucks and trailers on site. In the glossary

  6. Charging points for electric trucks, vans and cars. In the glossary

  7. The drivable area around the building for emergency vehicles. In the glossary

  8. Solar installations on a warehouse's large roof area. In the glossary

  9. Openings and devices that release smoke and heat in a fire. In the glossary

  10. Administrative, staff and sanitary areas within a logistics property. In the glossary

  11. An automatic extinguishing system that fights a fire where it starts. In the glossary

  12. Structural and technical protection of site and building. In the glossary

  13. The usable height of a warehouse up to the underside of the roof girders. In the glossary

  14. The spacing of the columns along and across the hall. In the glossary

  15. The storage equipment, usually pallet racking, in the hall. In the glossary

  16. The load the floor slab can carry per square metre and per rack foot. In the glossary

  17. The permitted deviation of the floor surface from a flat plane. In the glossary

  18. An automatic extinguishing system that fights a fire where it starts. In the glossary

  19. Energy-efficient warehouse lighting, usually with presence and daylight control. In the glossary

  20. Openings in roof and facade for natural light. In the glossary

  21. A system that detects fires automatically and alerts the fire brigade. In the glossary

  22. An intermediate floor inserted into the hall. In the glossary

  23. The movable platform bridging the gap between dock and vehicle. In the glossary

01

Building and structure

Height, grid and floor determine how much can be stored and how efficiently. They are hard to change later and are therefore the most important criteria when comparing buildings.

FeatureWhat mattersTypical in modern buildings
Clear height (UKB)Usable height up to the roof structure, less sprinklers and installationsaround 10 to 12 m, high-bay considerably more
Column gridColumn spacing that suits racking and aisleswide grids, e.g. 12 × 24 m
Floor loadingDistributed load, point load under rack feet, forklift wheel loadoften 5 t/m² distributed load
Floor flatnessTolerances for forklifts and rackingDIN 18202, for very narrow aisles DIN 15185
Building depthRelationship of dock side, staging and storagedepends on single- or double-sided loading
MezzanineAdditional level for picking, returns or officesuser-specific
Office and welfare areasOffices, break rooms, sanitary, changing roomsusually around 5 to 10% of warehouse area

02

Loading and yard

Doors and yard determine throughput. A building with too few docks or a tight truck court slows operations, however good it is otherwise.

FeatureWhat mattersTypical in modern buildings
Loading dockNumber, position and condition of dock doorsdock doors with levellers and shelters
Dock ratioDoors relative to area and throughputrule of thumb around 1 dock per 1,000 m²
Level access doorAccess for vans, forklifts and bulky goodsseveral per hall section
Truck courtYard depth for safe manoeuvring and dockinggenerally at least around 35 m in front of docks
Truck and trailer parkingBuffer for waiting trucks and dropped trailersaccording to operating concept
Fire access roadEmergency access around the buildingaccording to fire protection concept

03

Fire safety and security

Fire protection decides what may be stored, how high and in which compartments. It is one of the most frequent causes of delays and retrofits, particularly for plastics, hazardous goods and batteries.

FeatureWhat mattersTypical in modern buildings
Sprinkler systemDesign matched to goods and storage heighte.g. to VdS CEA 4001 or FM Global
ESFR sprinklersCeiling sprinklers for high storage without in-rack sprinklersdepends on occupier and insurer
Fire compartmentSize and position of compartments, fire walls, fire doorsunder the German industrial building guideline
Smoke and heat exhaust (SHEVS)Smoke and heat exhaust, air inletsroof vents, inspected regularly
Hazardous goods storagePermitted substances, quantities and sectionsunder TRGS 510 and permit
Fire water retentionRetention of contaminated firefighting waterrequired for water-hazardous substances
Battery storageFire protection for lithium-ion goods and returnsagree with insurer

04

Energy and ESG

Power is becoming a location factor. Automation, cooling and electric trucks need capacity that not every grid connection provides. At the same time, investors and corporate occupiers demand reliable ESG data.

FeatureWhat mattersTypical in modern buildings
Grid connectionAvailable capacity and time to upgradeclarify with the network operator
Rooftop solarUsable roof area, operator and power use modelincreasingly standard in new builds
Roof load capacityLoad reserve for solar and plantoften planned in new builds
EV charging for trucks and fleetsCharging points, ducts, transformer locationincreasingly in demand
LED lightingEfficient, controlled lightingstandard in new builds
Heating and heat pumpsConditioning without fossil fuelsdepends on temperature requirement
DGNB, BREEAM and LEEDCertification for ESG reportingDGNB, BREEAM or LEED

05

Location, permits and operation

The best building is of little use if it may not operate at night or cannot find staff. Planning law, connectivity and the labour market therefore belong in every specification.

FeatureWhat mattersTypical in modern buildings
Zone category (industrial and commercial)Industrial or commercial zone, permitted emissionsusually industrial zone for 24/7
24/7 operationPermitted operating hours and noise conditionscheck night operation explicitly
Zoning planType and extent of use, heights, building linesread before any decision
Site coverage and building volume ratios (GRZ, BMZ)Buildable area and permitted volumeassess together with yard and parking
Trimodal and rail sidingAccess to motorway, rail and waterwayrail sidings rare and valuable
Freight village (GVZ)Location in a freight villageshort distances to terminals and partners

Checklist for viewings

  1. Measure girder and clear height at several points
  2. Test the column grid against the planned racking layout
  3. Ask for evidence of distributed, point and wheel loads
  4. Check docks, levellers and shelters are working
  5. Walk the yard depth, entry, exit and parking
  6. Compare the sprinkler design with your product range
  7. Ask for fire compartment plans and exhaust and alarm inspection records
  8. Read permitted operating hours and use in the building permit
  9. Clarify grid connection capacity and upgrade options
  10. Review energy certificate, consumption data and certificates

Frequently asked questions

What is the most important metric of a logistics building?
There is no single metric. Clear height, floor loading, column grid and door count together determine how much can be stored and how fast goods move. Fire protection and permits are equally decisive for the use.
What clear height do I need?
It depends on goods, racking system and fire protection. Modern logistics buildings usually offer around 10 to 12 m. Cross-docking or production often needs less, high-bay warehouses considerably more.
How many doors does a logistics building need?
A rough rule of thumb is one dock door per 1,000 m² of warehouse space. Planned throughput is what counts, however. Throughput-heavy uses such as parcel hubs or cross-docking need far more doors.
Why is fire protection so important?
It determines which goods may be stored and how high. A sprinkler system that does not suit the product range can mean costly retrofits or limits on insurance cover, especially for plastics and batteries.
What does re-lettability mean?
It describes how easily a building can be let or sold to others after the occupier leaves. Standard features such as a good grid, sufficient height, floor load and flexible fire compartments increase it.
How does LÈMANS help find the right building?
Through an exclusive search mandate we translate your operating concept into a requirement profile, review the entire market including off-market properties and check every option against these specifications.

Requirements defined. Space wanted.

We translate your operating concept into a requirement profile and review the entire market, including beyond the portals.

Arrow keys to select, Enter to open